PoE via existing 2-wire lines
Existing buildings normally no longer meet the usual infrastructural requirements. For precisely these applications, ALLNET offers a quick and easy-to-install solution for integrating all PoE-capable end devices into the network cost-effectively and flexibly with its PoE via 2-wire.
The highlight: with the ALLNET MC-30 series, you can use the existing telephone or bell wire cabling to supply end devices such as modern video door intercoms with data and the required power at the same time. IP cameras or IP telephones, for example, can also be integrated into the network infrastructure in the same way. You do not have to lay any new cables; the existing cables are absolutely sufficient and offer the identical range of functions as new cabling. With the ALLNET MC-30 series, you can immediately bring your infrastructure up to date.
PoE over 2 Wires
Highlights:
Overview
The ALL-MC302v2P2WIRE set offers you the option of setting up both data and PoE via a 2-wire connection. The max. Cable length can be max. 500m. The master must be supplied with power via a power supply unit and supplies both the slave adapter and the PoE end device on the slave with data and power. The set is suitable for upgrading analogue systems through an existing cable infrastructure. The compact size of the media converter is perfect for replacing old door stations with a new IP door station.
Dimension:
Interface description:
Connection diagram:
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Receiver <- -> Transmitter
|
Cable 2×0.75 mm²
|
||
Receiver power supply type
|
DC 48-56 (30 W)
|
DC 48-56 (60 W)
|
|
Distance
100 M
|
Bandwidth (Mbps)
|
83
|
83
|
PoE (W)
|
27
|
27
|
|
Distance
200 M
|
Bandwidth (Mbps)
|
82
|
82
|
PoE (W)
|
26.5
|
27
|
|
Distance
300 M
|
Bandwidth (Mbps)
|
80
|
80
|
PoE (W)
|
26.3
|
27
|
|
Distance
400 M
|
Bandwidth (Mbps)
|
78.2
|
78.2
|
PoE (W)
|
22.8
|
27
|
|
Distance
500 M
|
Bandwidth (Mbps)
|
76
|
76
|
PoE (W)
|
18.2
|
26.5
|
|
Receiver <- -> Transmitter
|
Coaxial cable
|
||
Receiver power supply type
|
DC 48-56 (30 W)
|
DC 48-56 (60 W)
|
|
Distance
100 M
|
Bandwidth (Mbps)
|
84.2
|
84.2
|
PoE (W)
|
26.6
|
27
|
|
Distance
200 M
|
Bandwidth (Mbps)
|
83.4
|
83.4
|
PoE (W)
|
26.2
|
27
|
|
Distance
300 M
|
Bandwidth (Mbps)
|
82
|
82
|
PoE (W)
|
26
|
27
|
|
Distance
400 M
|
Bandwidth (Mbps)
|
80
|
80
|
PoE (W)
|
22.2
|
27
|
|
Distance
500 M
|
Bandwidth (Mbps)
|
79
|
79
|
PoE (W)
|
17.8
|
26
|
|
Note:
Actual data speed and PoE performance may vary depending on environmental conditions and cable quality.
Technical details:
Ethernet
|
|
Network standards
|
IEEE 802.3 10BaseT IEEE 802.3u 100BaseTX IEEE 802.3af Power over Ethernet PoE IEEE 802.3at Power over Ethernet PoE IEEE1901 PLC
|
Up down Agreement |
CSMA/CA |
Transmission / Rate |
500Mbps Physical Bandwidth 88Mbps Transmission Speed |
Cabling
|
Cat5 or above
|
Maximum Distance
|
100m
|
Connector
|
1x RJ45
|
Twisted pair
|
|
Cabling
|
Twisted pair
|
Connector
|
2-pin terminal block
|
Distance
|
up to 500m@24AWG
|
Datarate downlink
|
Up to 500Mbps
|
Datarate Uplink
|
Up to 500Mbps
|
Technology |
Powerline Communication (PLC)
|
Electric and Mechanical
|
|
Input Power
|
48-57VDC (terminal block) |
Power Consumption
|
=3.5W / PC
|
PoE standard
|
IEEE802.3af / IEEE802.3af "ONLY FOR v.2 SERIES" |
Output power
|
Standard 48VDC; IEEE802.3af / IEEE802.3at "from v2 series" |
Port
|
RJ45
|
Dimming (W x D x H)
|
123mm x26mmx 26mm |
Weight
|
0.25kg |
Casing
|
Aluminium case |
Environmental
|
|
Operating Temperature |
-20°C to 60°C |
Relative Humidity
|
<95% (Non-condensation) |