Element
|
Specification
|
Standards:
|
IEEE 802.3 10BaseT
IEEE 802.3u 100BaseTX
IEEE 802.3ab 1000BaseT
IEEE 802.3z 1000BaseSX/LX
IEEE 802.3x Flow Control Back Pressure
IEEE802.af for PoE
IEEE802.3at for PoE+
|
Network Connections:
|
1x 10/100/1000BaseT (RJ-45)
1x 1000BaseSX/LX SFP Module Slot
|
Data Processing:
|
Half/Full-Duplex on TP
|
PoE:
|
IEEE802.3at/af compatile
|
Flow Control: |
IEEE802.3x Flow Control and Back Pressure |
Jumbo Frame |
9KB |
Packet Buffer Size |
1M |
MAC adress Table Size |
2K |
Network Cable:
|
TP:10/100/1000BaseT Cat. 5, 5E, 6 UTP/STP, till 100 m
1000BaseSX:
62.5/125?m Multi Mode LWL, till 220 m
50/125?m Multi Mode LWL, till 550 m
1000BaseLX:
9/125?m Single Mode LWL
|
POE Pin Assignment: |
60 watts 4 pairs
V+, V+, V-, V- for pin 1, 2, 3, 6
V+, V+, V-, V- for pin 4, 5, 7, 8 |
DIP Switch: |
To select SFP speed 100M or 1000M. |
Reverse polarity protection: |
Present |
Overload current protection: |
Present |
LED:
|
PW1(power 1) Green: ON- power good, OFF-power failed
UTP LEDS: Amber ON- PD detected, Green ON ? Link/active
SFP LED: Green ON ? SFP detected
|
Power Supply:
|
4pin Terminal Block 48V-56V VDC Power Input
SW (Relay): Relay switch for alarm
|
Power Consumption: |
2W@48VDC without PoE |
PoE Power: |
Maximum PoE Power 72W at 56VDC Input |
Alarm Relay Contact: |
Relay outputs with current carrying capacity of 1 A @24VDC,
Relay in short circuit mode when power fails. in open circuit mode when power supply is connected |
Removable Terminal Block: |
Provide 4 pin terminal block
Wire range: 0.34mm^2 to 2.5mm^2
Solid wire (AWG):12-24/14-22
Stranded wire(AWG): 12-24/14-22
Torque:5lb-In/0.5Nm/0.56Nm
Wire Strip length: 7-8mm |
Case Dimension (L X W X D)mm
|
103.5mmx32mmx81.5mm (LxWxD) |
Installation mounting: |
DIN Rail mounting and Wall Mounting |
Housing: |
Rugged Metal, IP30 Protection |
MTBF ( mean time between failure) |
510,304 hrs ( MIL-HDBK-217F) at 25°C |
Environment:
|
Operating Temperature: -40° ~ +75° °C
Operating Humidity: 5% ~ 95% (non condensing)
Storage Temperature: -40 ~ 85 °C
Storage Humidity: 5% ~ 95% (non condensing)
|
Marks:
|
CE, FCC, VCCI
EN55022 Class A
EN55022/24 ITE Equipment
EN55011 Industrial, Scientific and Medical (ISM) equipment
IEC EN60950-1 Sicherheit
|
Shock:
|
EN50155 / EN 60068-2-27
|
Free Fall:
|
EN5055 / EN 60068-2-32
|
Vibration: |
EN 50155 / IEC 60068-2-6 |
EMI: |
FCC Part 15 Supbart B Class A
CE EN 55022 Class A |