Core Managed Layer3 Switch mit 28x SFP Slots für Kupfer oder Fibre SFP´s, 12x Feste RJ45 Gigabit Ports und 4x 10G SFP+ Slots
Highlights:- 28x 1G SFP ports +12x 10/100/1000M RJ45 ports + 4x 10G SFP+ ports
- Support L3 switching feature, including VLAN, port aggregation, port mirroring, port isolation, port flow control, port rate limiting, multicast, QOS, & access control list, etc
- Support Spanning Tree, for examples, STP, RSTP, MSTP etc.
- Management support through WEB, CLI, TELNET, SNMP.
- Max. Support 4x 10G SFP+ ports
- Support of extended management through WEB, CLI, TELNET, SNMP
- Support IPV4 / IPV6 forwarding.
- As access or aggregation switch in campus networks or as access switch in data centers.
The ALL-SG9940M-10G is a very versatile switch that is also perfectly suited as a core switch. This results from its various connection possibilities.
Various Port Types and Flexible Port Expansion
ALL-SG9440M-10G supports 28*1G SFP ports and 12*1000M RJ45 ports and 4x10G SFP+ ports. The users can flexibly adopt 1~4*10G ports expansion. The series also provides multiple gigabit ports (24 or 48 Base-T ports and Base-X ports), it can be used as an access or aggregation switch on campus networks or an access switch in data centers.
Comprehensive QoS policies and security mechanisms
ALL-SG9440M-10G supports strict ARP learning, which prevents ARP spoofing attacks that exhaust ARP entries,It also provides IP source guard to prevent DoS attacks caused by MAC address spoofing, IP address spoofing, and MAC/IP spoofing. The ALL-SG9440M-10G supports DHCP snooping, which generates user binding entries based on users' access interfaces, MAC addresses, IP addresses, IP address leases, and VLAN IDs. DHCP snooping discards invalid packets that do not match any binding entries, such as ARP spoofing packets and IP spoofing packets.This prevents hackers from using ARP packets to initiate man-in-the-middle attacks on campus networks.The interface
connected to a DHCP server can be configured as a trusted interface to protect the system against bogus DHCP server attacks.
Comprehensive reliability mechanisms
Besides STP,RSTP, and MSTP, the ALL-SG9440M-10G supports enhanced Ethernet reliability technologies such as Ethernet Ring Protection Switching (ERPS), also referred to as G.8032. As the latest ring network protocol, ERPS was developed based on traditional Ethernet MAC and bridging
functions and uses mature Ethernet OAM function and a ring automatic protection switching (R-APS) mechanism to
implement millisecond-level protection switching. ERPS supports various services and allows flexible networking, helping customers build a network with lower OPEX and CAPEX.
Powerful support for services
ALL-SG9440M-10G supports IGMP v1/v2/v3 snooping, IGMP filter, IGMP fast leave, and IGMP proxy. The ALL-SG9440M-10G supports wire-speed replication of multicast packets between VLANs, multicast load balancing among member interfaces of a trunk, and controllable multicast, meeting requirements for IPTV and other multicast services
Easy deployment and maintenance free
Supports SNMP v1/v2/v3 and provides flexible methods for managing devices. Users can manage the The ALL-SG9440M-10G using the CLI and Web NMS. Supports SSH2.0 and other encryption, which makes management much more secured. Supports LLDP protocol for simpler management
Technical Details:
Technical Details:Model |
ALL-SG9440M-10G |
Copper Ports |
12×10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports |
Fiber Ports |
28x100M/1000M BASE-X SFP interfaces, supports 100m/1000M dual mode
4x1G/10GBASE-X SFP interfaces, supports 1G/10Gbps dual mode
|
Console Ports |
1 x RS-232-to-RJ45 serial port (115200, 8, N, 1) |
Switch Architecture |
Store-and-Forward |
Switch Fabric |
160Gbps/non-blocking |
Throughput |
119Mpps @64 bytes |
Address Table |
32K entries |
Share Data Buffer |
32 Mb |
Jumbo Frame |
9600 Bytes |
SDRAM |
2Gb |
Flash Memory |
128Mb |
Flow Control |
IEEE 802.3x pause frame for full-duplex, Back pressure for half-duplex |
Reset Button |
>2 sec.: Factory default and reset |
Power Supply |
100~240V AC, 50/60Hz, 4A (max.) |
Power Consumption |
Max. 75 watts/1122 BTU |
LED Indicators |
Power: Green
Solid on- power work normal, off- power disconnected
System: Green
Blink-work normally, solid on- soft work abnormal, fast blink- soft upgrade
10/100/1000T RJ45 Interfaces (Port 1 to Port 12): 1000 LNK/ACT (Green),
10/100 LNK/ACT (yellow),
Blink- port connected with data transmission; Solid on- port connected without data transmission
100/1000Mbps SFP Interfaces (Port 12 to Port 40): Green
Blink- port connected with data transmission; Solid on- port connected without data transmission
1G/10G SFP Interfaces (Port 41 to Port 44): Blue
Blink- port connected with data transmission; Solid on- port connected without data transmission
|
EMC |
Surge Immunity: IEC61000-4-5
ESD Protection: ESD IEC61000-4-2
EFT IEC61000-4-4
|
Dimension |
440x240x44.5mm |
Weight |
3.2kg |
Working Temperature |
-10 ?to 45? |
Storage Temperature |
-20? to 70 ? |
MTBF |
50,000hrs |
Layer 2 functionsPort configuration |
Auto-negotiation
Flow Control
Port Mirror: TX/RX/BOTH; Many-to-1 monitor
CPU Mirror
Traffic statistics
|
Link Aggregation |
Static link aggregation
LACP(Dynamic Trunk/Static Trunk)
Algorith based on Source/Destination MAC
Algorithm based on Source/Destination IP
|
MAC Table |
Aging Time
Static MAC address
Dynamic MAC address management
|
VLAN |
4094 Active VLANs
4094 VID
802.1Q Tag VLAN
Port VLAN
Protocol VLAN
MAC VLAN
Voice VLAN
802.1ad Q-in-Q tunneling
Private VLAN (Protected port)
GARP/GVRP
|
ACL |
512ACLs
L2, L3 e L4
Time-based ACL
IP ACL
MAC ACL
MAC-IP ACL
User-Defined ACL
ICMPv6
|
Spanning tree |
802.1D Spanning Tree Protocol (STP)
802.1w Rapid Spanning Tree Protocol (RSTP)
802.1s Multiple Spanning Tree Protocol (MSTP)
Loop Guard
Root Guard
TC-BPDU Guard
BPDU Guard
BPDU Filter
|
Ring Protection |
<20ms G.8032 ERPS Ring
Fast Ring
|
Multicast |
1024 groups
IGMP v1/v2/v3 Snooping, Fast Leave
MLD Snooping
Multicast VLAN
IGMP filter
MVR
Multicast Routing
|
QOS |
8 mapping IDs to 8 level priority queues
CoS port-based
CoS 802.1p-based
CoS DSCP-based
Scheduling algorithms SP, WRR, SP+WRR
Storm Control (Broadcast, Multicast, Unknown Unicast)
Bandwidth control per port
SWRR, DWRR for Scheduling
Flow Redirect
Precedence
TOS
Rate Limiting(Ingress/Egress)
Stri Priority
|
Security Features |
Port Security
MAC address filter
ARP Association (Manual, ARP scanning, DHCP snooping)
ARP Protection
AAA
DAI
DoS (Denial of Service)
Classification of packages based on: End.MAC, IP End, TCP / UDP Ports,
Protocol Type;
802.1x Authentication (port-based e MAC-based)
TACACS/TACACS+ Authentication
RADIUS Authentication
DHCP Filter
Guest VLAN
SSLv2/SSLv3/TLSv1
SSHv1/SSHv2
Restriction of WEB access based on: IP Address, And. MAC and Port;
Port Isolation
Loopback detection
|
Management |
SNMP v1/v2c/v3 with Full Private MIBs
RMON 4 groups
WEB (HTTP/HTTPS)
CLI (Telnet, Console, SSHv1/v2)
Firmware upgrade via console/web/TFTP
Configuration Backup/Reload
Dual Firmware
LLDP
Configuration Export/Import
CDP Aware
OAM (IEEE802.3ah)
CFM (IEEE802.1ag)
SFlow
Telnet client
|
Synchronization,
IEEE1588
|
Support IEEE1588v2 transparent clock |
Other Features |
DNS Client
DHCP Relay
DHCP Client
DHCP Snooping
DHCP Option 66
DHCP Option 67
DHCP Option 82
NTP/SNTP Client
UPNP
UDLD
|
Maintenance |
Cable Diagnostics
Ping
SFP DDM (Digital Diagnostics Monitoring)
Thermal protection
System log (Local and Remote)
Memory and CPU Monitoring
Tracert /tracert 6
|
Layer 3 functions
Static Routing |
IPv4 Unicast: Static Routing(Software Base)
IPv6 Unicast: Static Routing(Software Base)
|
IPV6 |
IPv6 neighbor discovery (ND)
Path maximum transmission unit (MTU) discovery
Internet Control Message Protocol (ICMP) version 6
TCPv6/UDPv6
Ping6
Telnet(v6)
Http/Https
Interface IPV6
ACL IPV6
|
|
| | ALLNET Switch Modul ALL4750 Mini-GBIC Modul,1000Mbit,SX/LC, | | | ALLNET Switch Modul ALL4750-INDU SFP(Mini-GBIC), 1000Mbit, SX/LC, Industrial -40/+85 Grad, | | | ALLNET Switch Modul ALL4751 Mini-GBIC Modul,1000Mbit,LX/LC, 10Km | | | ALLNET Switch Modul ALL4751-INDU SFP(Mini-GBIC), 1000Mbit, LX/LC, 10Km, Industrial, -40/+85 Grad, | | | ALLNET Switch Modul ALL4752 SFP(Mini-GBIC), 1000Mbit, LHX/LC, 20KM, | | | ALLNET Switch Modul ALL4752-INDU SFP(Mini-GBIC), 1000Mbit, LHX/LC, 20KM, Industrial, -40/+85 Grad, | | | ALLNET Switch Modul ALL4753 Mini-GBIC Modul,1000Mbit, EX/LC, 40KM | | | ALLNET Switch Modul ALL4755 Mini-GBIC Modul,1000Mbit, ZX/LC, 70-80KM | | | ALLNET Switch Modul ALL4756 SFP(Mini-GBIC), 1000Mbit, EZX/LC,120KM | | | ALLNET ALL4757 / Switch Modul SFP+(Mini-GBIC), 10Gbit, SR/LC, | | | ALLNET Switch Modul ALL4757-INDU SFP+(Mini-GBIC), 10Gbit Multimode, SR/LC, Industrial -40/+85 Grad, | | | ALLNET Switch Modul ALL4758 SFP+(Mini-GBIC), 10Gbit Singlemode, LR/LC, bis 20Km | | | ALLNET Switch Modul ALL4758-INDU SFP+(Mini-GBIC), 10Gbit Singlemode, LR/LC, Industrial -40 -+85Grad, DDM, bis 20Km | | | ALLNET Switch Modul ALL4760 SFP+(Mini-GBIC), 10Gbit Singlemode, bis 220m, LRM/LC, *nur für Multimode 50/125u Kabel OM1-4* | | | ALLNET Switch Modul ALL4761 SFP(Mini-GBIC), 1000Mbit, WDM(Bidi)/LC, Tx1310nm/Rx1490nm, 9u, 20Km, | | | ALLNET Switch Modul ALL4761-INDU SFP(Mini-GBIC), 1000Mbit, WDM(Bidi)/LC, Tx1310nm/Rx1490nm, 9u, 20Km, Industrial -40/+85 Grad, | | | ALLNET Switch Modul ALL4762 SFP(Mini-GBIC), 1000Mbit, WDM(Bidi)/LC, Tx1490nm/Rx1310nm, 9u, 20Km, | | | ALLNET Switch Modul ALL4762-INDU SFP(Mini-GBIC), 1000Mbit, WDM(Bidi)/LC, Tx1490nm/Rx1310nm, 9u, 20Km, Industrial -40/+85 Grad, | | | ALLNET Switch Modul ALL4763 SFP+(Mini-GBIC), 10Gbit, B(Bidi)A/LC, Tx1270nm/Rx1330nm, 9u, 20Km, | | | ALLNET Switch Modul ALL4764 SFP+(Mini-GBIC), 10Gbit, B(Bidi)B/LC, Tx1330nm/Rx1270nm, 9u, 20Km, | | | ALLNET Switch Modul ALL4765 SFP(Mini-GBIC), 1000Mbit, RJ45(TP), | | | ALLNET Switch Modul ALL4767 SFP+(Mini-GBIC), 10Gbit, RJ45(TP), uncodiert | | | ALLNET Switch Modul ALL4768 SFP+(Mini-GBIC), 10Gbit Singlemode, ER/LC, bis 40Km | | | ALLNET Switch Modul ALL4769 SFP+(Mini-GBIC), 10Gbit Singlemode, ZR/LC, bis 80Km | | | ALLNET Switch Modul ALL4794 SFP(Mini-GBIC), 100Mbit, FX/LC, 10Km, single Mode, bis 10Km | | | ALLNET Switch Modul ALL4794-INDU SFP(Mini-GBIC), 100Mbit, FX/LC, 10Km, singlemode, Industrial -40/+85 Grad, | | | Patchkabel RJ45 FTP(F/UTP) 0.25m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 0.5m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 1.0m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 2m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 3m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 5m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 7.5m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45 FTP(F/UTP) 10m grau, CAT5e, Synergy 21, | | | Patchkabel RJ45, 0.25m grau, CAT5e, S-FTP(SF/UTP), Synergy | | | Patchkabel RJ45, 0.5m grau, CAT5e, S-FTP(SF/UTP), Synergy 2 | | | Patchkabel RJ45, 1.0m grau, CAT5e, S-FTP(SF/UTP), Synergy 2 | | | Patchkabel RJ45, 2m grau, CAT5e, S-FTP(SF/UTP), Synergy 21, | | | Patchkabel RJ45, 3m grau, CAT5e, S-FTP(SF/UTP), Synergy 21, | | | Patchkabel RJ45, 5m grau, CAT5e, S-FTP(SF/UTP), Synergy 21, | | | Patchkabel RJ45, 7.5m grau, CAT5e, S-FTP(SF/UTP), Synergy 2 | | | Patchkabel RJ45, 10m grau, CAT5e, S-FTP(SF/UTP), Synergy 21, | | | Patchkabel RJ45, 15m grau, CAT5e, S-FTP(SF/UTP), Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 0.25m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 0.5m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 1.0m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 2m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 3m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 5m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz, 7.5m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz,10m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | Patchkabel RJ45, CAT6 250Mhz,15m grau, S-STP(S/FTP), LSZH, Synergy 21, | | | TP(RJ45) POE-Tester, at/af, Endspan/Midspan, standard, Synergy 21, |
Downloads Back |